Digital Workflow Guides Graftless Mandibular Implants in Preliminary
A prospective consecutive case series of ten patients demonstrated that an integrated digital planning and static computer-guided surgical workflow enabled successful dental implant placement in posterior mandibular sites with minor horizontal bone deficiencie
Illustrative imageA prospective consecutive case series of ten patients demonstrated that an integrated digital planning and static computer-guided surgical workflow enabled successful dental implant placement in posterior mandibular sites with minor horizontal bone deficiencies without requiring lateral ridge augmentation. In the preliminary clinical investigation, ten consecutive partially edentulous individuals presenting with a calculated horizontal ridge deficiency of 4 millimeters or less received single implant restorations planned through merged cone-beam computed tomography and intraoral optical scans. The exploratory protocol intentionally optimized three-dimensional implant positioning within the existing native osseous envelope rather than adhering rigidly to a standard prosthetic trajectory, achieving a 100 percent implant survival rate and a 100 percent prosthetic survival rate through twelve months of functional masticatory loading without intraoperative or postoperative surgical complications.
Standard post-extraction healing within the posterior mandible frequently results in alveolar ridge resorption and horizontal bone loss that complicates ideal prosthetically driven implant rehabilitation. Conventional surgical management for horizontal deficiencies often relies on lateral ridge augmentation procedures, such as guided bone regeneration, autogenous block bone grafting, cortical shell techniques, or ridge expansion, to establish sufficient alveolar bone volume. Furthermore, secondary surgical interventions introduce distinct clinical risks, including postoperative wound dehiscence, barrier membrane exposure, graft resorption, surgical site infection, and donor-site complications. The clinical investigation sought to determine whether comprehensive virtual diagnostics could reliably identify specific localized anatomies where surgical bone grafting might be entirely avoided.
The study protocol prospectively recruited ten adult patients, comprising seven males and three females with a mean age of 46.7 years and a standard deviation of 10.6 years, who presented for single-tooth replacement in healed posterior mandibular sites. Eligibility required a minimum patient age of 18 years, a healed edentulous site in the posterior mandibular arch, a calculated horizontal ridge deficiency not exceeding 4 millimeters, and completion of at least one full year of clinical follow-up after definitive prosthetic crown loading. Exclusion criteria eliminated prospective candidates exhibiting active periodontal disease, uncontrolled systemic diseases that contraindicated elective oral surgical procedures, heavy cigarette smoking exceeding 10 cigarettes per day, or an inability to attend scheduled recall appointments across the one-year evaluation timeline.
Preoperative digital diagnostics integrated volumetric three-dimensional bone imaging and precision optical surface scanning. High-resolution cone-beam computed tomography scans were captured using a Planmeca ProMax 3D Classic unit and exported in standard Digital Imaging and Communications in Medicine format. Corresponding dental surface anatomies were captured intraorally with a Medit i700 Wireless optical scanner and exported as Standard Tessellation Language data files. These multimodal datasets were coregistered and aligned inside BlueSky Plan treatment software to construct an anatomically detailed three-dimensional virtual patient representation. This digital framework allowed the surgical team to simulate prosthetically driven crown restorations while concurrently evaluating cross-sectional alveolar bone dimensions, residual cortical morphology, planned implant trajectory, and adjacent vital anatomical structures.
Virtual implant positioning commenced by measuring crestal bone width at the prospective edentulous site to assess native tissue availability. Within the investigative protocol, ideal required ridge width was calculated by adding 1.5 millimeters of necessary bone margin to both the buccal and lingual aspects of the planned implant diameter. The calculated horizontal ridge deficiency was defined specifically as the linear difference between this theoretical ideal osseous envelope and the actual measured crestal bone width, serving as an operational planning metric rather than an anatomical classification of defect morphology. Across the ten treated patients, preoperative crestal ridge width averaged 4.7 millimeters with a standard deviation of 0.4 millimeters and an observed range from 4.1 to 5.3 millimeters, yielding a mean calculated horizontal ridge deficiency of 2.26 millimeters with a standard deviation of 0.21 millimeters and a range from 1.8 to 2.6 millimeters.
When the ideal axial trajectory failed to reside completely within the available native bone boundary, clinicians selectively modified the virtual fixture trajectory, buccolingual placement, and apicocoronal insertion depth to maximize bone engagement while maintaining prosthetic restorability. Standard commercial fixtures from either the bredent copaSKY or Neodent implant systems were planned, utilizing implant diameters ranging between 3.5 and 4.5 millimeters and lengths between 10 and 12 millimeters. Fully guided surgical templates supported by adjacent natural dentition were subsequently designed within the software and fabricated through additive stereolithography on an Anycubic Photon Mono SE three-dimensional printer. Each fabricated surgical template underwent rigorous clinical intraoral seating verification to confirm absolute passive fit and mechanical stability prior to surgical intervention.
Surgical interventions were performed under local anesthesia with 4 percent articaine containing 1:100,000 epinephrine via full-thickness mucoperiosteal flaps. Osteotomies and fixture placement were executed exclusively through the tooth-supported templates using proprietary fully guided surgical drill sets according to manufacturer specifications. All ten procedures proceeded without surgical deviations, intraoperative accidents, or intraoperative conversion to freehand surgical instrumentation, and no supplemental grafting materials or barrier membranes were applied. Surgical sites were closed primarily using 5-0 polypropylene single interrupted sutures. Following an uneventful three-month delayed healing phase, customized definitive abutments were computationally designed and precision-milled from titanium blanks to correct the intentional implant angulation, restore the target emergence profile, and support cemented single-unit definitive crowns.
To evaluate restorative biomechanical compensation, the study documented the prosthetic correction angle, defined as the angular divergence between the long axis of the tilted implant fixture and the corrected long axis of the planned prosthetic crown restoration. Across the patient series, the mean prosthetic correction angle measured 19.2 degrees with a standard deviation of 3.8 degrees, spanning from an individual minimum of 15 degrees to a maximum of 25 degrees. The clinical team treated this measurement strictly as a descriptive planning parameter reflecting individual restorative compensation rather than an established clinical boundary or standardized therapeutic threshold. Standardized digital periapical radiographs and three-dimensional cone-beam computed tomography scans acquired twelve months after functional occlusal loading confirmed stable crestal bone levels, maintenance of intact buccal and lingual cortical plates, complete osseous containment, and an absence of peri-implant radiolucency, fenestration, or cortical dehiscence.
During the twelve-month functional follow-up period, the clinical series experienced zero prosthetic or mechanical maintenance events. The authors highlighted that while the clinical and radiographic outcomes remained entirely favorable across the observation window, several potential confounding factors were present in the clinical protocol.
The study authors highlighted several critical methodological limitations inherent to the prospective investigation. The research design comprised a small, single-center case series of ten patients without a parallel comparative control group undergoing standard lateral ridge augmentation. Radiographic assessments were qualitative rather than quantitative, lacking linear three-dimensional millimeter measurements of buccal plate remodeling or marginal crestal bone changes over extended intervals.
Subject of Research: Digital planning and computer-guided graftless implant placement in posterior mandibular horizontal bone deficiencies
Article Title: A fully digital workflow for implant rehabilitation of posterior mandibular ridges with minor horizontal deficiencies without lateral ridge augmentation: A prospective consecutive case series
Article References: Shalash, M., & Shehabeldin, M. (2026). A fully digital workflow for implant rehabilitation of posterior mandibular ridges with minor horizontal deficiencies without lateral ridge augmentation: A prospective consecutive case series. Digital Dentistry Journal, 4(1), Article 100127. https://doi.org/10.1016/j.ddj.2026.100127
Image Credits: AI Generated
DOI: 10.1016/j.ddj.2026.100127
Keywords: digital implantology, guided surgery, cone-beam computed tomography, intraoral scanning, posterior mandible, lateral ridge augmentation, horizontal bone deficiency, prosthetic correction angle, custom CAD/CAM abutments, implant survival, prosthetic survival, delayed loading, crestal bone stability, surgical templates, titanium abutments
News Source: Ophelia Keating. (November 23, 2026). Digital Workflow Guides Graftless Mandibular Implants in Preliminary Prospective Clinical Series. Scienmag.